INTERLABORATORY COMPARISON OF RADIATED EMISSION MEASUREMENTS USING A TUBULAR DIPOLE
......: info......: history......: editorial......: archive......: for authors......: subscription
   
Image NTRP

Vol. XXXVII, No. 3, Pp. 175-257
September 2022
UDC 621.039+614.876:504.06
ISSN 1451-3994

Back to Contents

 


Pages: 207-214

Authors:
Aleksandar M. Kovačević, Nenad V. Munić, Nenko S. Brkljač
and Koviljka Dj. Stanković

Abstract

This paper presents an interlaboratory comparison of radiated emission measurements in the frequency range of 30-1000 MHz. A tubular dipole was specifically designed and employed as a reference emitting source. The most important for a tubular dipole is stability in the testing process. The stability is not the performance of the sample, but the emission signal of the sample is stable. In addition, two ways of determining the reference value of the electromagnetic field strength are considered. The first reference value is obtained by using robust analysis. It is a robust average value that is calculated by averaging the measurement results provided by the participating testing laboratories. The other reference value is obtained through the simulation-experimental results of the tubular dipole in the semi-anechoic chamber or full anechoic chamber, for horizontal and vertical polarizations and 3 m distance measurement, respectively. In addition, this value is assigned by the coordinator. Measurement results are compared using the robust z-scores and ς-scores, respectively.

Key words: interlaboratory comparison, testing laboratory, radiated emission, tubular dipole, robust analysis, simulation-experimental result

FULL PAPER IN PDF FORMAT (2.01 MB)

Vinča Institute of Nuclear Sciences :: Designed by milas :: July 2007
Operated by acapanic :: Last updated on February, 2023