NT & RP Journal
A COMPARISON OF RETROSPECTIVE RADON GAS MEASUREMENT TECHNIQUES CARRIED OUT IN THE SERBIAN SPA OF NISKA BANJA
......: info......: history......: editorial......: archive......: for authors......: subscription

Vol. XXIV, No. 2, Pp. 75-155
September 2009
UDC 621.039+614.876:504.06
ISSN 1451-3994

....Back to Contents

 


Pages: 94-99

Authors:
Zora S. ŽUNIĆ, Kevin KELLEHER, Igor ČELIKOVIĆ, Predrag UJIĆ, Johan PARIDAENS, James P. McLAUGHLIN, Olivera ČUKNIĆ, Gordana MILIĆ, Jugoslav NIKOLIĆ, Rodoljub SIMOVIĆ

Abstract

Indoor radon retrospective concentrations were obtained and compared using two radon measurement methods. Both methods rely on the measurement of the long-lived radon progeny 210Pb, collected either on the surfaces (surface trap technique), most frequently glass, or in a volume trap, usually sponge from furniture (volume trap technique). These techniques have been used to retrospectively estimate radon gas concentrations that have existed in dwellings in the past. The work presented here compares the results provided by the surface trap technique devised at the University College of Dublin, Ireland, and the volume trap technique devised at the Scientific Research Center, Mol, Belgium. The field campaign was carried out by the research team of the ECE Laboratory of the Vinča Institute of Nuclear Sciences at the spa of Niska Banja, identified as a region of Serbia with a high indoor radon and ground water radium and radon content

Key words: indoor radon, retrospective measurement, surface trap, volume trap

FULL PAPER IN PDF FORMAT (497 KB)

Vinča Institute of Nuclear Sciences :: Designed by milas :: July 2007
Last updated on September, 2010